Inputs | - analogue - J, K, S, B thermocouples, Pt100 resistance sensor
- digital - 5 x input with possibility to wait for state change in the program
Outputs | - open collector - for SSR (solid state relay) use
- electro-magnetic relay - 250 V / 5 A - contactor operation at the program run
(limited temperature checking)
- phase controlled (0-100 %)
- voltage
output 0-10 V - direct, galvanicly separated
- 5 x digital output controlled by the program
(e.g. ALARM) optionally with SSR, electro-magnetic relay or transistor
with open collector
Operation | - readable 12-buttons keyboard with icons
Display | - double LED - red and green
Regulation | - own algorithms, improved PID regulation
- possibility to set limit temperature in which contactor switches off
(in breakdown of SSR)
Programs | - 10 programs with 15 steps (basic version)
- 80 programs with 50 steps (extend version)
- in case that step
amount is not enough it is possible to jump to another program (use Jump command
at the end of the program)
Communication | - 1 x MASTER, 15 - SLAVE with regulation difference
- possibility to add another display and keyboard
- operation from the superordinate PC: RS 232 (galvanic separation optional)
or RS 422 - galvanicly separated
Accuracy | - calibration accuracy ±0,1 % from range
- temperature stability 0,3°C / 10°C of surrounding temperature change
Surrounding | - 0-50°C, 0-90 % RH
Voltage | - 230 V / 50-60 Hz - power input 3 VA
Dimensions | - 96 x 96 x 165 mm - DIN 1/4
Guarantee | - CE certification, 3 years
|
|
|
|
|
|
|
|
|
|
|
|